The NetApp unified driver for Data ONTAP operating in 7-Mode with iSCSI is a driver interface from OpenStack Cinder to NetApp Data ONTAP operating in 7-Mode storage controllers to accomplish provisioning and management of a storage-area network (SAN) block storage entity; that is, a NetApp LUN that uses the iSCSI protocol.
To set up the NetApp Data ONTAP operating in 7-Mode iSCSI driver for Cinder, the following stanza should be added to the Cinder configuration file (cinder.conf
):
[myIscsiBackend] volume_backend_name=myIscsiBackend volume_driver=cinder.volume.drivers.netapp.common.NetAppDriver netapp_server_hostname=hostname
netapp_server_port=80
netapp_storage_protocol=iscsi netapp_storage_family=ontap_7mode netapp_login=admin_username
netapp_password=admin_password
Be sure that the value of the | |
The value of | |
The value of |
Table 4.9, “Configuration options for Data ONTAP operating in 7-Mode with iSCSI” lists the configuration options available for the unified driver for a clustered Data ONTAP deployment that uses the iSCSI storage protocol.
Option | Type | Default Value | Description |
netapp_server_hostname |
Required | The hostname or IP address for the storage system or proxy server. The value of this option should be the IP address of either the cluster management LIF or the SVM management LIF. | |
netapp_server_port |
Optional | 80 | The TCP port to use for communication with the storage system or proxy server. If not specified, Data ONTAP drivers will use 80 for HTTP and 443 for HTTPS; E-Series will use 8080 for HTTP and 8443 for HTTPS. |
netapp_login |
Required | Administrative user account name used to access the storage system or proxy server. | |
netapp_password |
Required | Password for the administrative user account specified in the netapp_login option. |
|
netapp_storage_protocol |
Required | nfs |
The storage protocol to be used. Valid options are nfs or iscsi . If None is specified or the option is omitted, nfs will be used. |
netapp_transport_type |
Optional | http |
Transport protocol for communicating with the storage system or proxy server. Valid options include http and https . |
netapp_size_multiplier |
Optional | 1.2 | When creating volumes, the quantity to be multiplied to the requested OpenStack volume size to ensure enough space is available on the SVM (aka Vserver). This value is currently only used when ISCSI has been selected as the storage protocol to be used. |
netapp_volume_list |
Optional | This option is only utilized when the storage protocol is configured to use iSCSI. This option is used to restrict provisioning to the specified controller volumes. Specify the value of this option to be a comma separated list of NetApp controller volume names to be used for provisioning. | |
netapp_vfiler |
Optional | The vFiler unit on which provisioning of block storage volumes will be done. This option is only used by the driver when connecting to an instance with a storage family of Data ONTAP operating in 7-Mode. Only use this option when utilizing the MultiStore feature on the NetApp storage system. | |
netapp_storage_family |
Optional | ontap_cluster |
The storage family type used on the storage system; valid values are ontap_7mode for Data ONTAP operating in 7-Mode, ontap_cluster for clustered Data ONTAP, or eseries for E-Series. |